The HRR-W is a temperature control device mountable in a 19-inch rack. Rack mounting recovers desktop or floor space, permitting stacking of related devices and mobility, depending on the rack style. Recirculating fluid removes heat from the process source, which is then removed from the fluid by a water-cooled refrigeration circuit. Coolant temperature stability is ±
3.10.1 LRC(ASCII) .3-10 3.10.2 CRC(RTU) .3-10 3.11 Explanation of function codes . 3-12 3.11.1 Function code04 Reading multiple registers .3-12 3.11.2 Function code06 Writing registers .3-13 3.11.3 Function code16 Writing multiple registers .3-14 HRR Series HRX-OM-W004 Contents 3.11.4 Function code23 Reading/writing multiple registers . 3-15 3.12 Negative response . 3-16 3.13 Register Map
Contents 9.4 Cooling capacity . 9-9 9.4.1 HRR010-A -10. 9-9 9.4.2 HRR010-W-10. 9-9 9.4.3 HRR010-A -20. 9-10 9.4.4 HRR010-W-20. 9-10 9.5 Heating capacity . 9-11 9.5.1 HRR010-A-10. 9-11 9.5.2 HRR010-W-10. 9-11 9.5.3 HRR010-A-20. 9-12 9.5.4 HRR010-W-20. 9-12 9.6 Pump capacity. 9-13 9.6.1 HRR010-A/W-10 . 9-13 9.6.2 HRR010-A/W-10-T1 . 9-13 9.7 Required facility water flow (for water-cooled type
0 0 10 15 25 20 30 40 35 10 15 25 20 30 40 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRR010-W-20 [50 Hz] [60 Hz] 400 400 35C Heating capacity [W] Heating capacity [W] 35C 300 300 25C 25C 200 200 5C 5C 100 100 Facility water temperature Facility water temperature Facility water temperature Facility water temperature 0 0 10 15 25 20 30 40 35 10 15 25 20 30 40 35
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: None