The HEC-W2 thermoelectric chiller is a low capacity, refrigerant-free temperature control device suitable for benchtop service. This model uses a water-cooled peltier element to regulate coolant for a heat generating instrument or process requiring high precision temperature regulation. Select this model for 600 or 1200W of cooling capacity when facility water can be connected to prevent overheating
Model HEC006-W2A HEC006-W2B HEC012-W2A HEC012-W2B Cooling method Thermoelectric device (Thermo-module) Radiating method Water-cooled Control method Cooling/Heating automatic shift PID control 50 to 95F (10 to 35C), 35 to 80%RH (no condensation) Ambient temperature/humidity Clear water, Fluorinated fluid (FluorinertFC-3283, GALDEN HT135) Circulating fluid Note 1) 50 to 140F (10 to 60 C) (no
A_HEC-OM-L008 Rev.D Feb.2016 HEC002-A THERMO-CON Model No. HEC001-W5* HEC003-W5* Keep this manual available at all times. Preface Preface Thank you very much for purchasing SMC Thermo-con (herein referred to as the product). This manual describes the operation of the product. Please use this manual for efficient and long use of this unit. Be sure to read this manual efficiently for your
Cooling Capacity: 012 (1200W), Communication: A (RS-485), Option: N (NPT Thread)
Cooling Capacity: 1200W, Communication: RS-485, Option: NPT Thread
Series HEC is a range of Peltier type chillers which are ideal for ensuring the constant temperature of circulating fluids. The series is available in either an air cooled (refrigerant free type), or a water cooled?version. Available in a wide range of power supply voltages, the HEC offers outstanding cooling capacity performance of between 230 and 1200W depending on the selected model.
Pump for HEC012-W, THERMO CONTROLLER, PELTIER TYPE, 701, 6 lb
Solid State Relay for HEC006/HEC012, THERMO CONTROLLER, PELTIER TYPE, 701, 200 lb
Cooling Capacity: 012 (1200W), Communication: B (RS-232C)
Cooling Capacity: 1200W, Communication: RS-232C, Option: -
Cooling Capacity: 006 (600W), Communication: A (RS-485)
Cooling Capacity: 600W, Communication: RS-485, Option: -
Cooling Capacity: 012 (1200W), Communication: B (RS-232C), Option: N (NPT Thread)
Cooling Capacity: 1200W, Communication: RS-232C, Option: NPT Thread
Cooling Capacity: 006 (600W), Communication: A (RS-485), Option: N (NPT Thread)
Cooling Capacity: 600W, Communication: RS-485, Option: NPT Thread
USB drivers for communication cables (LEC-W2A-C and LEC-W2-C) can also be downloaded.
The controller setting software can be downloaded from here.
Note) Even if you download the controller setting software, a communication cable (LEC-W2A-C) or USB cable (LEC-W2-U) is always required.
We recommend using the LEC-W2A-C (Windows 10 communication cable) for use with Windows 10.
After purchasing the cable, download the driver for the communication cable (LEC-W2A-C) onto a USB, and install it.
As for the old communication cable (LEC-W2-C), installing a driver for Window 8.1 on a Windows 10 PC may be possible, but operation is not guaranteed.