The EX600 serial interface offers a full suite of diagnostics and programmable parameters to meet the most stringent requirements. Up to 1024 (512/512 I/O blocks) and 7 valve manifolds can be connected. The EX600 can be configured as a centralized or a de-centralized I/O system, or a combination of both. This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000
Note 2) Cannot be connected with the EX600-SPR1, EX600-SPR2, EX600-SDN1, or EX600-SDN2. Refer to page 15 for a table of mountable units. 1 Fieldbus System Series EX600 How rder AX EX600 Analog Input Unit Analog input Number of input channels and connector Number of input channels 2 channels Connector Symbol A M12 connector (5 pins) 2 pcs.
Applicable wire 0.08 to 1.5 mm2 (AWG16 to 28) Current consumption 50 mA or less 55 mA or less Enclosure IP40 (Manifold assembly) Standards CE Marking, UL (CSA), RoHS compliant Weight 300 g EX600-DXlF 13 Fieldbus System Series EX600 Series EX600 Series SY Series SV Series S0700 Series VQC Digital Output Unit Model EX600-DYPB EX600-DYNB EX600-DYPE EX600-DYNE EX600-DYPF EX600-DYNF Output type
SI Unit EX600-SPRA EX600-SPR (PROFIBUS DP) (PROFIBUS DP) EX600-SMJ EX600-SEN (CC-Link) (EtherNet/IP) EX600-SDNA EX600-SDN (DeviceNet) (DeviceNet) EX600-DXB EX600-DXC EX600-DXD EX600-DXE Digital unit EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600-AXA Analog unit EX600-AYA EX600-AMB EX600-HT1 H.T. EX600-HT1A H.T.
The EX600 serial interface offers a full suite of diagnostics and programmable parameters to meet the most stringent requirements. The EX600 offers excellent flexibility including digital input, digital output and analog input unit options. With the use of D-sub output blocks, a maximum of 9 remote D-sub manifolds can be attached to one EX600 communication module.
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. New Style piping adapter attachment , Easy maintenance , Detach equipment
-35No.EX-OMN0035CN-A (1)EX600-DYB EX600-DYPB EX600-DYNB 1 NC 24 V() 2 2 2 3 0 V() NC 4 1 1 5 FE FE M12 (4 ) EX600-DYPB EX600-DYNB 1 1 24 V NC 2 2 2 2 DC24 V DC24 V 3 3 NC 0 V 4 4 1 1 5 5 FE FE FE FE IP67 OFF ON SI -36No.EX-OMN0035CN-A (2)EX600-DYE EX600-DYPE EX600-DYNE 1 0 2 2 3 4 4 6 5 8 6 10 7 12 8 14 9 NC 10 NC 11 NC 12 NC 13 0 V() 24 V() 14 1 15 3 16 5 17 7 18 9 19 11 20
SI EX600 0 0 -9No.EX-OML0010CN-C EX600-HT1 EX600-HT1A EX600-SPR EX600-SPRA EX600-SDN EX600-SDNA SI EX600-SMJ EX600-SEN EX600-SEC EX600-SPN EX600-DXB EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF (EX600-DYPE1) EX600-DME EX600-DMF (EX600-AXA) (EX600-AYA) (EX600-AMB) EX600-HT1 EX600-DEEX600-DFEX600-AYAEX600-AMB EX600-HT1A EX600-HT1A
Type: W (Wireless), SI Unit: PN (Wireless Base Unit, for PROFINET), Output: 2 (NPN)
Type: W (Wireless), SI Unit: EN (Wireless Base Unit, for EtherNet/IPâ„¢), Output: 1 (PNP)
Type: W (Wireless), SI Unit: EN (Wireless Base Unit, for EtherNet/IPâ„¢), Output: 2 (NPN)
Type: W (Wireless), SI Unit: PN (Wireless Base Unit, for PROFINET), Output: 1 (PNP)
End plate Mounting Position: ED (Mounting Position D Side), Power Supply: 2 [M12 (5 Pins) B-coded, IN]
End plate Mounting Position: ED (Mounting Position D Side), Power Supply: 3 [7/8 inch, (5 Pins), IN]
End plate Mounting Position: ED (Mounting Position D Side), Power Supply: 5 [M12 (4/5 Pins) A-coded, IN/OUT]
End plate Mounting Position: ED (Mounting Position D Side), Power Supply: 4 [M12 (4/5 Pins) A-coded, IN/OUT]
End plate Mounting Position: EU1 (Mounting Position U Side)
Type: S (Wired), Protocol: DN (DeviceNetâ„¢), Output Polarity: 1 [PNP (-COM)]