The EX600 serial interface offers a full suite of diagnostics and programmable parameters to meet the most stringent requirements. Up to 1024 (512/512 I/O blocks) and 7 valve manifolds can be connected. The EX600 can be configured as a centralized or a de-centralized I/O system, or a combination of both. This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000
Note 2) Cannot be connected with the EX600-SPR1, EX600-SPR2, EX600-SDN1, or EX600-SDN2. Refer to page 15 for a table of mountable units. 1 Fieldbus System Series EX600 How rder AX EX600 Analog Input Unit Analog input Number of input channels and connector Number of input channels 2 channels Connector Symbol A M12 connector (5 pins) 2 pcs.
*SY3100-5U1 3 sets (2-position single part number) *SY3200-5U1 2 sets (2-position double part number) *EX600-DXPD 1 set I/O Unit part number (Station 1) *EX600-DYPB 1 set I/O Unit part number (Station 2) 2-position single SY3100-5U1 (3 sets) Digital Output Unit EX600-DYPB Digital Input Unit EX600-DXPD The asterisk denotes the symbol for assembly.
Circuit diagram EX600-DXPB/EX600-DXPD EX600-DXNB/EX600-DXND Precautions for handling Be sure to fit a seal cap on any unused connectors.
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. New Style piping adapter attachment , Easy maintenance , Detach equipment