The EX600 serial interface offers a full suite of diagnostics and programmable parameters to meet the most stringent requirements. Up to 1024 (512/512 I/O blocks) and 7 valve manifolds can be connected. The EX600 can be configured as a centralized or a de-centralized I/O system, or a combination of both. This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000
Note 2) Cannot be connected with the EX600-SPR1, EX600-SPR2, EX600-SDN1, or EX600-SDN2. Refer to page 15 for a table of mountable units. 1 Fieldbus System Series EX600 How rder AX EX600 Analog Input Unit Analog input Number of input channels and connector Number of input channels 2 channels Connector Symbol A M12 connector (5 pins) 2 pcs.
-SPNl 12 A Series EX600 Digital Unit Specifications Digital Input Unit Model EX600-DXPB EX600-DXNB EX600-DXPCl EX600-DXNCl EX600-DXPD EX600-DXND Input type PNP NPN PNP NPN PNP NPN Input connector M12 (5-pin) socket Note 1) M8 (3-pin) socket Note 3) M12 (5-pin) socket Note 1) Number of inputs 8 inputs (2 inputs/Connector) 8 inputs (1 input/Connector) 16 inputs (2 inputs/Connector) Supplied
Circuit diagram EX600-DXPB/EX600-DXPD EX600-DXNB/EX600-DXND Precautions for handling Be sure to fit a seal cap on any unused connectors.
EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600-AXA EX600-AYA EX600-AMB H.T.
SI EX600 0 0 -9No.EX-OML0010CN-C EX600-HT1 EX600-HT1A EX600-SPR EX600-SPRA EX600-SDN EX600-SDNA SI EX600-SMJ EX600-SEN EX600-SEC EX600-SPN EX600-DXB EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF (EX600-DYPE1) EX600-DME EX600-DMF (EX600-AXA) (EX600-AYA) (EX600-AMB) EX600-HT1 EX600-DEEX600-DFEX600-AYAEX600-AMB EX600-HT1A EX600-HT1A
Type: W (Wireless), SI Unit: PN (Wireless Base Unit, for PROFINET), Output: 2 (NPN)
Type: W (Wireless), SI Unit: EN (Wireless Base Unit, for EtherNet/IPâ„¢), Output: 1 (PNP)
Type: W (Wireless), SI Unit: EN (Wireless Base Unit, for EtherNet/IPâ„¢), Output: 2 (NPN)
Type: W (Wireless), SI Unit: PN (Wireless Base Unit, for PROFINET), Output: 1 (PNP)
End plate Mounting Position: ED (Mounting Position D Side), Power Supply: 2 [M12 (5 Pins) B-coded, IN]
End plate Mounting Position: ED (Mounting Position D Side), Power Supply: 3 [7/8 inch, (5 Pins), IN]
End plate Mounting Position: ED (Mounting Position D Side), Power Supply: 5 [M12 (4/5 Pins) A-coded, IN/OUT]
End plate Mounting Position: ED (Mounting Position D Side), Power Supply: 4 [M12 (4/5 Pins) A-coded, IN/OUT]
End plate Mounting Position: EU1 (Mounting Position U Side)
Type: S (Wired), Protocol: DN (DeviceNetâ„¢), Output Polarity: 1 [PNP (-COM)]
Type: S (Wired), Protocol: PR (PROFIBUS DP®), Output Polarity: 1 [PNP (-COM)]
Type: S (Wired), Protocol: EN (EtherNet/IP™), Output Polarity: 3 (PNP, -Com; EtherNet/IP™, Dual Port; PROFINET Conformance Class C, EtherCAT®)