The EX510 series makes it possible to connect more valves and sensors than with conventional units. With the introduction of the EX510 series, only a power supply cable to the GW unit is required, resulting in wire-savings. Setting the address for the SI unit, output unit and input unit is no longer required, only the address for the GW unit needs to be set. The volume ratio of the EX510
Decentralized Serial Wiring (GW System, 4 Branches) Series EX510 How to Order GW Unit Communication protocol MJ1 EX510-G MJ1 DN1 PR1 CC-Link DeviceNet PROFIBUS DP Power supply connector Specifications EX510-GMJ1 EX510-GDN1 EX510-GPR1 Model CC-Link Ver. 1.10 DeviceNet Release 2.0 PROFIBUS DP DP-V0 Protocol Version Note 1) Applicable system Communication connector Communication specification
Accessories EX Communication Connector Pin Assignment Communication protocol Pin assignment and the corresponding wire color q Part no. w e r t EX510-GMJ1 EX510-GDN1 EX510-GPR1 CC-Link DA (Blue) DB (White) DG (Yellow) SLD FG DeviceNet V(Black) CAN_L (Blue) Drain CAN_H (White) V+ (Red) PROFIBUS DP VP DGND RxD/TxD-P (Red) SHIELD RxD/TxD-N (Green) q w r t e 1703 Series EX510 EX510-GMJ1 (CC-Link
EX510-DXN EX510-DXP EX510-DXB1 Applicable sensor NPN output PNP output 2 wire type Number of input points 16 points (See diagram below for details.)
Similar items in stock.
Accessories EX Communication Connector Pin Assignment Communication protocol Pin assignment and the corresponding wire color q Part no. w e r t EX510-GMJ1 EX510-GDN1 EX510-GPR1 CC-Link DA (Blue) DB (White) DG (Yellow) SLD FG DeviceNet V(Black) CAN_L (Blue) Drain CAN_H (White) V+ (Red) PROFIBUS DP VP DGND RxD/TxD-P (Red) SHIELD RxD/TxD-N (Green) q w r t e 1703 Series EX510 EX510-GMJ1 (CC-Link