EX260 series is a compact and cost effective fieldbus solution for output applicable to SMC's most popular directional control valves such as New SY, SV, VQC, and S0700 Series. It can control up to 32 solenoids in one manifold. Available protocols are EtherNet/IP™, PROFINET®, EtherCATConfigure Options...
SI Unit Integrated-type/For Output Series EX260 Note) RoHS Compact design Compact design for space saving Number of outputs Each 32/16 digital output type available in the series Output polarity Each negative common (PNP) / positive common (NPN) type available in the series Enclosure IP67 (For units with D-sub connector, and when connected with S0700 manifolds, it is IP40.)
SI Unit Specifications Model EX260-SPR1/3 EX260-SPR2/4 EX260-SPR5/7 EX260-SPR6/8 EX260-SDN1/3 EX260-SDN2/4 EX260-SMJ1/3 EX260-SMJ2/4 PROFIBUS DP DeviceNet CC-Link Protocol Applicable system Volume 1(Edition 3.5) Volume 3(Edition 1.5) DP-V0 Ver.1.10 Version Note 1) GSD file EDS file Configuration file Note 3) SMJ1: 32/32 SMJ3: 32/32 (1 station, remote I/O stations) SMJ2: 32/32 SMJ4: 32/32
-A Summary of Product elements <EX260-SPL1/-SPL3> No.
Type: S (Wired), Protocol: PL (POWERLINK), Output Polarity: 1 [PNP (-COM)], Suffix: -X26 (Powerlink)
Type: Wired, Protocol: POWERLINK, Output Polarity: 1 [PNP (-COM)], Suffix: Powerlink
JSY3000 manifold with EX260 and connecting bracket to connect with ZK2 vacuum generator manifold. EX260 compact valve interface; Available with EtherNet/IP, Profinet, EtherCAT, IO-Link, Powerlink and other protocols
JSY3000 manifold with EX260 and connecting bracket to connect with ZK2 vacuum generator manifold. EX260 compact valve interface; Available with EtherNet/IP, Profinet, EtherCAT, IO-Link, Powerlink and other protocols
Protocol: SPL (POWERLINK), Output Polarity/Communication Connector: 3 [16 Outputs, -COM (PNP), M12 Connector]
Protocol: SEN (EtherNet/IPâ„¢, Modbus/TCP), Output Polarity/Communication Connector: 1 [32 Outputs, -COM (PNP), M12 Connector]
Protocol: SEC (EtherCAT®), Output Polarity/Communication Connector: 1 [32 Outputs, -COM (PNP), M12 Connector]
Protocol: SEN (EtherNet/IPâ„¢, Modbus/TCP), Output Polarity/Communication Connector: 3 [16 Outputs, -COM (PNP), M12 Connector]
Protocol: SPN (PROFINET®), Output Polarity/Communication Connector: 1 [32 Outputs, -COM (PNP), M12 Connector]
Protocol: SMJ (CC-Link), Output Polarity/Communication Connector: 1 [32 Outputs, -COM (PNP), M12 Connector]
Protocol: SEC (EtherCAT®), Output Polarity/Communication Connector: 2 [32 Outputs, +COM (NPN), M12 Connector]
Protocol: SEN (EtherNet/IPâ„¢, Modbus/TCP), Output Polarity/Communication Connector: 4 [16 Outputs, +COM (NPN), M12 Connector]
Protocol: SEC (EtherCAT®), Output Polarity/Communication Connector: 3 [16 Outputs, -COM (PNP), M12 Connector]