Series CVS1 is a double acting, single rod, valve mounted cylinder with built-in speed controller. Operation style can be changed to normally retracted or normally extended. Single, double, and 3 position solenoid valves can be installed. There are seven mounting options available for the CVS1 series and bore sizes range from 40mm to 100mm. An auto switch cylinder with the switch installed
110 150 2 110 + 30(n2) (n = 2, 4, 6, 8 ) 150 + 100(n2) (n = 2, 4, 6, 8 ) D-A3 D-G39 D-K39 35 + 30(n2) Different surfaces n 110 + 100(n2) (n = 2, 4, 6, 8 ) 150 + 30(n2) (n = 2, 4, 6, 8 ) Same surface 100 + 100(n2) 1 110 150 15 35 55 Different surfaces Same surface 150 110 2 150 + 30(n2) (n = 2, 4, 6, 8 ) 110 + 30(n2) (n = 2, 4, 6, 8 ) 35 + 30(n2) Different surfaces D-A44 n 150 + 50(n2) (n
(Page 11) 7 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig 1. Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.
Contents Bore size (mm) @6 @7 28 @9 #0 31 #2 33 Lube type Piston seal Rod seal CVS1-40-PS 40 50 63 80 100 CVS1-40-PS CVS1-50-PS CVS1-63-PS CVS1-80-PS CVS1-100-PS CVS1-50-PS Cushion seal Set of left nos. @6, @7, @9, #0, #2, #5 CVS1-63-PS Cylinder tube gasket 28, 31, 33 and 34 are non-replaceable parts, so they are not included in the seal kit.
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: N (Non-lube), Bore Size: 100mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: W (2 Position Double), Valve Type: D (
Magnet: D (Built-in), Mounting: D (Double Clevis), Style: N (Non-lube), Bore Size: 50mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: W (2 Position Double), Valve Type: D
Magnet: None, Mounting: L (Axial Foot), Style: N (Non-lube), Bore Size: 100mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: W (2 Position Double), Valve Type: D (DIN Connector
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube, Bore Size: 100mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 24VDC, Solenoid Style: 2 Position Double, Valve Type: DIN Connector, Cylinder
Magnet: Built-in, Mounting: Double Clevis, Style: Non-lube, Bore Size: 50mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 24VDC, Solenoid Style: 2 Position Double, Valve Type: DIN Connector, Cylinder
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Magnet: D (Built-in), Mounting: L (Axial Foot), Style: N (Non-lube), Bore Size: 100mm, Port Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 5 (24VDC), Solenoid Style: W (2 Position Double), Valve Type
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube, Bore Size: 40mm, Port Thread: -, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: A33--Reed, DC Volt >5 <24, LED, Terminal, None, Lead Wire or Prewired Connector: -, Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 24VDC, Solenoid Style: 2 Position Double, Valve Type: DIN Connector, Cylinder
Magnet: Built-in, Mounting: Double Clevis, Style: Non-lube, Bore Size: 50mm, Port Thread: -, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, 0.5M, Lead Wire or Prewired Connector: -, Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 24VDC, Solenoid Style: 2 Position Double, Valve Type: DIN Connector, Cylinder
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification