The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.
CEP112 CEP120
x 1 4-M6 x 1.0 depth 6.5 (Bottom 5.3 through-hole) 9.5 counterbore depth 5.5 (500 or 3000) 25 70 1.5 5 Width across flats 13 7 5 10 22f8 10f7 6 53 35.6 23 36 23 SR6 40 18 3 23 M8 x 1.25 70 36 18 7 2-M5 x 0.8 (Port size) 4-M5 x 0.8 Thread depth 10 74 20 114 + Stroke 31 145 + Stroke 2 10-12-14 High Precision Stroke Reading Cylinder Non-rotating Piston Type Series CEP1 Foot style: 4-5.5 CEP1L20
DOCUMENT No.: CE*-OMB0075-D OPERATION MANUAL PRODUCT NAME : Precision MONOSASHI-KUN MODEL : CEP1 Read this operation manual carefully to understand before installation and operation. Pay extra attention on the clause concerning the safety. Keep this operation manual available whenever necessary. SMC CORPORATION Contents Chapter 1: Read Before Use 1 Chapter 2: Product Summary 5 2-1. System
CEP112 CEP120 Foot Front flange Nil C Extension cable 5m Extension cable & connector 10m CEP1L12 CEP1F12 15m CEP1L20 CEP1F20 20m Applicable auto switch types Load voltage Maximum load current & load current range 0.5 (Nil) 3 (L) 5 (Z) Lead wire length (m) Applicable load Electrical entry direction AC DC Wiring (output) Special function Type Indicator light Lateral Vertical 24V or less 24V