The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.
CEP1 CEP1 CE1 CE1 How to Order CE2 B CEP1 12 50 M9BW ML2B Made to Order Refer to page 648 for details. High precision stroke reading cylinder Mounting type B L F Direct mounting rod side tapped type Foot type Rod side flange type Number of auto switches 2 pcs. 1 pc. n pcs.
M14 x 1 4-M5 x 0.8 depth 6 (Bottom 4.3 through-hole) 7.5 counterbore depth 4 (500 or 3000) 25 70 0.5 Width across flats 8 5 7 3 10 18f8 6f7 3.8 44 17 27 18 SR3.5 26.6 3 18 M5 x 0.8 13 40 17 27 5 67.5 14.5 4-M4 x 0.7 Thread depth 7.5 2-M5 x 0.8 (Port size) 71.5 103 + Stroke 24 127 + Stroke 2 10-12-12 High Precision Stroke Reading Cylinder Non-rotating Piston Type Series CEP1 Foot style: CEP1L12
L 3 m Connector Nil w/ connector Stroke(mm) Made To Order Fluoro rubber packing (Ex.) 2-2-2 Applicable Auto-Switch Models Z w/o connector 25, 50, 75, 100 Mark Auto-Switch Model Mark Auto-Switch Model Mark Auto-Switch Model A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW 2-color D-M9PW A96 Reed D-A96 M9B Solid State D-M9B M9BW Indication Solid State D-M9BW A90V Auto-Switch D-A90V
Example order: CE1B32-100-M9BW 1 unit BQ-2 2 pcs. BQ2-012 2 pcs. Note 2) Auto switch mounting brackets and auto switches are shipped together with cylinders. Note 3) D-A9 and D-A9V auto switches cannot be used with the product with a bore size of 12 (CE112).