The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.
mA PNP open collector Max. 30 VDC, 50 mA NPN open collector Max. 30 VDC, 50 mA PNP open collector Max. 30 VDC, 50 mA RS Q G Output transistor mode 80 to 120 VAC 50/60 Hz 21.6 to 26.4 VDC Power supply voltage RS H A 10 VA or less 5 W or less Power consumption RZQ Between case and AC line: 1500 VAC for 1 min.
The cylinder section does not have a water resistant enclosure. 3-3 Allowable Kinetic Energy 3-3-1 Allowable Kinetic Energy (J) Bore size(mm) 12 20 32 40 50 63 Allowable Kinetic EnergyE 0.022 0.055 0.15 0.26 0.46 0.77 3-3-2 Mass of Cylinder Movable Parts (g) Cylinder stroke (mm) Bore size(mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 28 33 38 43 48 53 20 70 84 98 112 126 140 154 168
10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50,7 5, 100, 125, 150 *90and 91-series MXQ6 products do not have shock absorbers.
Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: M9BWVL