Series AV-A soft start-up valves allow the user to set the initial rate of system pressurizations to minimize system shock. When deactivated, the valve quickly exhausts the system for safe servicing of equipment.
across flats 19 AV3000-m03-5 to 6G(Z)m-A AV4000-m04-1 to 4G(Z)m-A 50 60 64 54 8.5 18 90 3.2 39 74 M5 x 0.8 Depth 6.5 4 Width across flats 22 AV4000-m04-5 to 6G(Z)m-A AV5000-m06, 10-1 to 4G(Z)m-A 70 75 70 60 11 16 100 3.2 45 80 56 M6 x 1 Depth 8 6 Width across flats 32 AV5000-m06, 10-5 to 6G(Z)m-A 8 AV2000-A/3000-A/4000-A/5000-A Series Dimensions DIN terminal: AVm00-m-mD/Ymm-m-A Applicable
Regulator Unit Combination: [Other FRL Combination Devices] Soft Start Up Valve, Port Size: NPT3/4, Filter Rating: 5μm, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure
Size: 3/4, 1, Thread: NPT, Port Size: 3/4-AV5000 Only, Option: None, Voltage: 110~120VAC, Lead Wire: DIN Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Body Size: 5000, Thread: N (NPT), Port Size: 10 (1), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: NPT, Port Size: 1, Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: None, Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 06 (3/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: DO (Type D, DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)