Series AV-A soft start-up valves allow the user to set the initial rate of system pressurizations to minimize system shock. When deactivated, the valve quickly exhausts the system for safe servicing of equipment.
When a system hazard can be expected due to a drop in vacuum pressure caused by power loss or vacuum pump trouble, install a safety circuit and configure the system so that it can avoid the danger. 2. When a system hazard can be expected with a malfunction of the vacuum regulator, install a safety circuit and configure the system so that it can avoid the danger. 1.
Fluororubber is used for rubber seal materials. 80 IR 0 Ozone resistant X170 IR 0 Compatible with modular connection brackets Modular Combination Example Description Applicable model IR100--X170 AF20-A AFM20-A Y200-A Y200T-A IR20--X170 AF30-A AFM30-A Y300-A Y300T-A IR30--X170 AF40-A AFM40-A Y400-A Y400T-A qRegulator wAir filter eMist separator rInterface tInterface with bracket Note 1) The
If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.