Series AV-A soft start-up valves allow the user to set the initial rate of system pressurizations to minimize system shock. When deactivated, the valve quickly exhausts the system for safe servicing of equipment.
Flow Rate Characteristics Series AV2000-A AV3000-A AV4000-A AV5000-A Port size 1(P), 2(A) 1/4 3/8 1/2 3/4 1 3(R) 1/4 3/8 1/2 3/4 1(P) R 2(A) C[dm3/(sbar)] 9.2 13.1 19.2 34.8 41.3 b 0.36 0.27 0.32 0.66 0.34 Cv 2.4 3.1 5.1 12.6 13.7 Flow rate characteristics 2(A) R 3(R) C[dm3/(sbar)] 8.8 9.2 10.1 23.7 b 0.46 0.48 0.55 0.67 Cv 2.5 2.6 3.2 9.2 Pressure for switching from low speed air supply
Flow Rate Characteristics Series AV2000-A AV3000-A AV4000-A AV5000-A Port size 1(P), 2(A) 1/4 3/8 1/2 3/4 1 3(R) 1/4 3/8 1/2 3/4 1(P) R 2(A) C[dm3/(sbar)] 9.2 13.1 19.2 34.8 41.3 b 0.36 0.27 0.32 0.66 0.34 Cv 2.4 3.1 5.1 12.6 13.7 Flow rate characteristics 2(A) R 3(R) C[dm3/(sbar)] 8.8 9.2 10.1 23.7 b 0.46 0.48 0.55 0.67 Cv 2.5 2.6 3.2 9.2 Pressure for switching from low speed air supply
AV*-OMZ0091-A PRODUCT NAME Soft Start-up Valve MODEL / Series / Product Number AV2000-(F,N)02(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AV3000-(F,N)03(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AV4000-(F,N)04(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AV5000-(F,N)06~10(B,G,S)-1~6(G,D,Y,DO,YO)(Z)(B,C)(-R,Z)-A AVA2000-(F,N)02(B,G,S)(-R,Z)-A AVA3000-(F,N)03(B,G,S)(-R,Z)-A AVA4000-(F,N)04(B,G,S)(-R,Z
bore 1/8 R 4-R 4-R 36.8 E 36.8 E R P VEX P D D AMR + + MADE IN JAPAN ITV MADE IN JAPAN SMC SMC IC VBA Model Port size A B C D E G H I VE K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000