Series AV-A soft start-up valves allow the user to set the initial rate of system pressurizations to minimize system shock. When deactivated, the valve quickly exhausts the system for safe servicing of equipment.
Flow Rate Characteristics Series AV2000-A AV3000-A AV4000-A AV5000-A Port size 1(P), 2(A) 1/4 3/8 1/2 3/4 1 3(R) 1/4 3/8 1/2 3/4 1(P) R 2(A) C[dm3/(sbar)] 9.2 13.1 19.2 34.8 41.3 b 0.36 0.27 0.32 0.66 0.34 Cv 2.4 3.1 5.1 12.6 13.7 Flow rate characteristics 2(A) R 3(R) C[dm3/(sbar)] 8.8 9.2 10.1 23.7 b 0.46 0.48 0.55 0.67 Cv 2.5 2.6 3.2 9.2 Pressure for switching from low speed air supply
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: S (Silencer), Voltage: 5 (24 VDC), Lead Wire: KO (M12 Connector, w/o Cable), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 3/8, Option: Silencer, Voltage: 24 VDC, Lead Wire: M12 Connector, w/o Cable, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Push-turn Locking Lever Type, Flow Direction/Pressure Unit: Flow Direction: Right to Left
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: DO (Type D, DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: None, Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: YO (Type Y DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 4 [220 VAC (230 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Body Size: 3000, Thread: Rc, Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: R (Flow Direction: Right to Left)
Regulator Unit Combination: [Other FRL Combination Devices] Soft Start Up Valve, Port Size: Rc3/8, Filter Rating: 5μm, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Reverse Flow (Right to Left)] Right to left, Drain Cock: [Not Provided] No, Pressure Gauge