AS-X785 is a pilot operated check valve that is intended for direct mounting on the device being controlled. It is available in combinations of threaded and One-touch connections for installation versatility.
ASN AQ ASV AK How to Order VCHC F S 1 0 03 06 3 2 AS ASR ASQ Hexagon lock nut Round lock nut J Nil Lock nut option Speed controller Option None Electroless nickel plated Nil N Body size 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size Note) With seal 4 6 8 10 12 04 06 08 10 12 Made to Order Refertopage612for details.
AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 4 6 6 8 6 8 8 10 10 12 21 21.5 25.5 26 16 17 17 18.5 17 18.5 18.5 21 21 22 13 13 34 31 56 52 93 88 154 146 M5 x 0.8 11.2 28.3 25.5 25 22.2 9 13 8 KE R 1/8 33.9 32.4 27.4 26.6 14.6 15.5 12 13.8 35.5 30.5 TMH R 1/4 38.5 34.8 29.8 28.7 19.5 15.5 17 17.2 40.3
Doc. no. AS*-OMA0069-D PRODUCT NAME SPEED CONTROLLER STANDARD TYPE IN-LINE TYPE MODEL/ Series/ Product Number / / / Contents 1Safety Instructions 2 3 2Specific Product Precautions 4 5 3Application 6 4Specifications 6 5Malfunctions and Countermeasures 6 6Construction 7 8 -1- Speed Controller Standard Type In-Line Type / AS Series Safety Instructions These safety instructions are intended