SMC Corporation of America
Elite Part Number Search
Search Results "25A-ZK2B15K5KWA-08-B"

The 25A-ZK2 series is a single unit energy-saving generator with 93% reduced air consumption that is free of copper and zinc for use in the secondary battery manufacturing industry.  It has a 50% increase in suction flow compared to other single stage SMC generators.  The 25A-ZK2 also has various mounting options to choose from.

  • Series 25A-ZK2 is compatible with secondary batteries
Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output, Connector: With Lead Wire for Switch with Energy Saving Function, Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: -, Vacuum

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output, Connector: With Lead Wire for Switch with Energy Saving Function, Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: w/o Option

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / -14.5 to 14.5 (100 to -100) kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Without Pressure Sensor / Digital Pressure Switch for Vacuum, Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum with Energy Saving Function / -14.5 to 14.5 (100 to -100) kPa / NPN 1 Output, Connector: With Lead Wire for Switch with Energy Saving Function, Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / -14.5 to 14.5 (100 to -100) kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch

Body/Exhaust Type: Single Unit - Port Exhaust, Nominal Nozzle Size: ø1.5, Supply Valve and Release Valve: N.C. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output, Connector: With Lead Wire for Switch with Energy Saving Function, Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: -, Individual

Body/Exhaust Type: Single Unit - Port Exhaust, Nominal Nozzle Size: ø1.5, Supply Valve and Release Valve: N.C. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output, Connector: With Lead Wire for Switch with Energy Saving Function, Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: -, Individual

)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch