The MXQ precision slide table is integrated with guides and rails combined with recirculating bearings to isolate the load bearing from the movement of the dual rods and piston seals. The end lock option prevents the slide table from dropping in vertical applications, enhancing safety in the event of air pressure loss.
The 25A- series variations are designed using material compatible
(mm) MXQ20-40 MXQ20-75 MXQ20-40 MXQ20-75 MXQ20-75 MXQ20-30 0.06 MXQ20-100 MXQ20-125 MXQ20-150 0.06 MXQ20-50 MXQ20-50 MXQ20-100 MXQ20-150 0.08 MXQ20-30 MXQ20-125 0.04 0.04 MXQ20-20 MXQ20-20 MXQ20-100 MXQ20-10 0.04 0.02 MXQ20-10 0.02 0 0 0 100 200 300 100 200 300 400 500 600 100 200 300 Load (N) Load (N) Load (N) 25 25 25 Lr=200 mm 0.08 MXQ25-150 MXQ25-150 MXQ2550 MXQ2575 MXQ2510 MXQ2520 MXQ2530
dual 3-port valve Operating pressure range Internal pilot operating pressure range (MPa) 0.1 to 0.7 (High pressure type: 0.1 to 1) 100 kPa to 0.7 (4-position: 100 kPa to 0.6) 100 kPa to 0.7 (High pressure type: 100 kPa to 1) 2-position single 2-position double 3-position External pilot operating pressure range (MPa) Pilot pressure range 0.25 to 0.7 0.1 to 0.7 (High pressure type: 0.1 to
L3: Can be used within the Allowable overhang range in the selection graph if the load mass and driving speed values are within the allowable range For Transfer/ Without Adjuster MXQ 25A-mZm, MXQ 25-mZm Height interchangeable type Double-ported type MXQA MXQ20(A)-10, 20, 30, 40Z MXQ20(A)-50Z 7 7 V = mm/s V = mm/s 6 6 Load mass m [kg] Load mass m [kg] 5 5 4 4 V = 100 V = 100 3 3 Low thrust
size 32 3 to 4 1 125 15 to 17 3 100 8 to 10 2 80 6 to 8 1.5 63 4 to 5 1.5 50 3 to 5 1 40 3 to 4 1 100 st Extra 50 st 344 Series CL1 40 to 100 Replacement Procedure of Seal 3 6.