Series IR Precision Regulators are designed to be compact and light weight. The maximum set pressure has been expanded from the conventional 0.7MPa to 0.8MPa. Relief flow has been increased by nearly 5 times (compared to SMC IR201, IR401). The optional bracket and pressure gauge can be mounted on either the front or back of the unit.
The 25A- series variations are designed using material
) P O R T S I Z E R E G U L AT I N G P R E S S U R E R A N G E 01 1/8 (IR1000) 02 1/4 (IR2000, IR3000) 03 3/8 (IR3000) 04 1/2 (IR3000) For Series IR1000/2000 0 0.005~0.2 MPa / 0.7~30PSI 1 0.005~0.4 MPa / 0.7~60PSI 2 0.005~0.8 MPa / 0.7~120PSI For Series IR3000 0 0.01~0.2 MPa 1 0.01~0.4 MPa 2 0.01~0.8 MPa T H R E A D T Y P E Rc(PT) N NPT F (G)PF S Y M B O L S ACCESSORIES S E R I E S IR1000
When a system hazard can be expected due to a drop in vacuum pressure caused by power loss or vacuum pump trouble, install a safety circuit and configure the system so that it can avoid the danger. 2. When a system hazard can be expected with a malfunction of the vacuum regulator, install a safety circuit and configure the system so that it can avoid the danger. 1.