The 10-SV Clean Room series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations have been simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also
Function: 1 (2 Position Single), Pilot: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor)
Function: 2 Position Single, Pilot: External Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: -, Manifold Block: -, Manifold Wiring: -, A, B Port: -
Function: 1 (2 Position Single), Pilot: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: Double, A, B Port: C8 (ø8 One-touch Fitting)
Function: 1 (2 Position Single), Pilot: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: S (Single), A, B Port: C8 (ø8 One-touch Fitting)
Function: 1 (2 Position Single), Pilot: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: Double, A, B Port: N11 (3/8" One-touch Fitting)
Function: 1 (2 Position Single), Pilot: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: S (Single), A, B Port: N7 (1/4" One-touch Fitting)
Function: 2 Position Single, Pilot: External Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Tie Rod Base Type 10 Manifold Block, Manifold Wiring: Double, A, B Port: ø8 One-touch Fitting
Function: 2 Position Single, Pilot: External Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Tie Rod Base Type 10 Manifold Block, Manifold Wiring: Single, A, B Port: ø8 One-touch Fitting
Function: 2 Position Single, Pilot: External Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Tie Rod Base Type 10 Manifold Block, Manifold Wiring: Double, A, B Port: 3/8" One-touch Fitting
Function: 2 Position Single, Pilot: External Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Tie Rod Base Type 10 Manifold Block, Manifold Wiring: Single, A, B Port: 1/4" One-touch Fitting
Model: 1 (10-SV1000), Actuation: A (4 Position Dual 3 Port Valve: N.C./N.C.), Pilot Type: Internal Pilot, Back Pressure Check Valve: None, Voltage: 5 (24 VDC), Light/Surge Voltage Suppressor: U (W/Light/Surge Voltage Suppressor)
Model: 3 (10-SV3000), Actuation: 2 (2 Position Double Solenoid), Pilot Type: Internal Pilot, Back Pressure Check Valve: None, Voltage: 5 (24 VDC), Light/Surge Voltage Suppressor: U (W/Light/Surge Voltage Suppressor)
Model: 2 (10-SV2000), Actuation: 4 (3 Position Exhaust Center), Pilot Type: Internal Pilot, Back Pressure Check Valve: None, Voltage: 5 (24 VDC), Light/Surge Voltage Suppressor: U (W/Light/Surge Voltage Suppressor)
Model: 4 (10-SV4000), Actuation: 3 (3 Position Closed Center), Pilot Type: R (External Pilot), Back Pressure Check Valve: None, Voltage: 5 (24 VDC), Light/Surge Voltage Suppressor: U (W/Light/Surge Voltage Suppressor)
Model: 3 (10-SV3000), Actuation: 2 (2 Position Double Solenoid), Pilot Type: R (External Pilot), Back Pressure Check Valve: None, Voltage: 5 (24 VDC), Light/Surge Voltage Suppressor: U (W/Light/Surge Voltage Suppressor)
Model: 4 (10-SV4000), Actuation: 2 (2 Position Double Solenoid), Pilot Type: Internal Pilot, Back Pressure Check Valve: None, Voltage: 5 (24 VDC), Light/Surge Voltage Suppressor: U (W/Light/Surge Voltage Suppressor)
Model: 1 (10-SV1000), Actuation: 2 (2 Position Double Solenoid), Pilot Type: Internal Pilot, Back Pressure Check Valve: None, Voltage: 5 (24 VDC), Light/Surge Voltage Suppressor: U (W/Light/Surge Voltage Suppressor)