The 10-SV Clean Room series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations have been simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also
SS5V2-10 SS5V3-10 SS5V4-10 Note) The value is for manifold base with 5 stations and individually operated 2 position type.
Function: B (4 Position Dual 3 Port N.O./N.O.), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor)
Function: 4 Position Dual 3 Port N.O./N.O., Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: -, Manifold Block: -, Manifold Wiring: -, A, B Port: -
Function: B (4 Position Dual 3 Port N.O./N.O.), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: N7 (1/4" One-touch Fitting)
Function: B (4 Position Dual 3 Port N.O./N.O.), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: N3 (5/32" One-touch Fitting)
/N.O.), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: Double, A, B Port: N7 (1/4" One-touch Fitting)
Function: B (4 Position Dual 3 Port N.O./N.O.), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: C (Cassette Base Type 16 Manifold Block), Manifold Wiring: Double, A, B Port: C6 (ø6 One-touch Fitting)
/N.O.), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: Double, A, B Port: C6 (ø6 One-touch Fitting)
Function: 4 Position Dual 3 Port N.O./N.O., Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: 1/4" One-touch Fitting
Function: 4 Position Dual 3 Port N.O./N.O., Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: 5/32" One-touch Fitting
/N.O., Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Tie Rod Base Type 10 Manifold Block, Manifold Wiring: Double, A, B Port: 1/4" One-touch Fitting
Function: 4 Position Dual 3 Port N.O./N.O., Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Cassette Base Type 16 Manifold Block, Manifold Wiring: Double, A, B Port: ø6 One-touch Fitting
/N.O., Pilot: Internal Pilot, Voltage: 24VDC, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Manifold Block: Tie Rod Base Type 10 Manifold Block, Manifold Wiring: Double, A, B Port: ø6 One-touch Fitting
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), VALVE, VALVE, SV2000 SOLENOID VALVE, 5-PORT, 2I, SV2000 NO SIZE RATING, .14373 lb
Series: SV2000, Function: B (4 Position Dual 3 Port N.O./N.O.), Pilot: Internal Pilot, Voltage: 5 (24VDC), M12 Waterproof Connector: W1 (300), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Driver Operation Manual Button)
Series: SV2000, Function: B (4 Position Dual 3 Port N.O./N.O.), Pilot: Internal Pilot, Voltage: 5 (24VDC), M12 Waterproof Connector: W1 (300), Light & Surge Suppressor: U (Light & Surge Suppressor)
Function: B (4 Position Dual 3 Port N.O./N.O.), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Driver Operation Manual Button)