The CUJ miniature free mount, clean room series is a space saving compact cylinder. It is available in 6mm to 10mm bore sizes with stroke lengths up to 20mm. The CUJ series is double acting and auto switch capable.
Model Cushion Bore size (mm) 6 10 16 Action Standard stroke (mm) Auto switch mounting Port size Lubrication Model Rubber Air 10-/21-CDU6 10-/21-CDU10 10-/21-CDU16 Relief type Vacuum suction type 5, 10, 15, 20, 25, 30 10-/21-CDU20 20 5, 10, 15, 20, 25, 30, 40, 50 10-/21-CDU25 25 Non-lube Double acting Single rod M5 x 0.8 6 10 16 11-/22-CDU6 11-/22-CDU10 11-/22-CDU16 5, 10, 15, 20, 25, 30
For Axial Mounting With Auto Switch (Built-in Magnet) For Lateral Mounting A B 27 29 31 33 38 43 48 53 27 29 31 33 38 43 48 53 27 29 31 33 38 43 48 53 C D Cylinder model Mounting bolt size CDUJB6-4 -6 -8 -10 -15 -20 -25 -30 CDUJB8-4 -6 -8 -10 -15 -20 -25 -30 CDUJB10-4 -6 -8 -10 -15 -20 -25 -30 Cylinder model Mounting bolt size CDUJB6-4 -6 -8 -10 -15 -20 -25 -30 CDUJB8-4 -6 -8 -10 -15 -20
= IA x B I = 0.20 x 10-6 + 0.18x 10-6 = 0.38 x 10-6 (kg.m2) (: Unit conversion constant) MHC2-6D/MHCA2-6D Attachment inertial moment 0.38 x 10-6 (kg.m2) < Allowable inertial moment without speed controller 0.5 x 10-6 (kg.m2) c.Confirm from the table that the inertial moment of one attachment is within the allowable range.
MHZ2-25D/MHZL2-25D MHZ2-6D/MHZA2-6D 14 160 Pressure 0.7 MPa Pressure 0.7 MPa 12 140 0.6 MPa 0.6 MPa 10 Gripping force (N) Gripping force (N) 120 Pressure 0.7 MPa Pressure 0.7 MPa 0.5 MPa 0.5 MPa 100 8 0.6 MPa 0.6 MPa 0.5 MPa 0.4 MPa 0.4 MPa 0.5 MPa F 80 6 0.3 MPa 0.3 MPa 0.4 MPa 0.4 MPa 0.3 MPa 0.2 MPa 60 0.2 MPa 0.2 MPa 0.3 MPa 4 40 0.2 MPa 2 20 0 20 40 60 80 100 0 10 20 30 F Gripping point